technology

right Chemistry See all product

Jasco FVS-6000 VCD (Vibrational Circular Dichroism) Spectrometer

☆☆☆☆☆ ( 0 rates ) 272
Price : Call

Code: #14418

Supplier: JASCO International Co., Ltd.

JASCO has developed the FVS-6000 high performance VCD (Vibrational Circular Dichroism) spectrometer with the most advanced DSP electronics and auto-alignment mechanism. The FVS-6000 not only allows you to easily obtain fingerprint VCD spectra, but also has several unique features such as a measurement range extension option of 4000 ~ 750 cm-1.

rightMORE INFORMATION

  • JASCO has developed the FVS-6000 high performance VCD (Vibrational Circular Dichroism) spectrometer with the most advanced DSP electronics and auto-alignment mechanism. The FVS-6000 not only allows you to easily obtain fingerprint VCD spectra, but also has several unique features such as a measurement range extension option of 4000 ~ 750 cm-1. Since the CD signals in the infrared region are one or more orders of magnitude lower than ECD signals in the UV-Vis region, high sensitivity and stability are required for a VCD spectrometer. The FVS-6000 is the VCD spectrometer of choice for highly sensitive VCD measurements.
    Optimized optics
    The FVS-6000 employs a 28° interferometer to reduce polarization effects and reflective optics to eliminate artifacts caused by birefringence for high-quality VCD data. The isolated mount of the IR light source and the thermal control of the PEM crystal offers long-term baseline stability.
    VCD auto alignment
    The auto alignment function optimizes the VCD optics to reduce linear anisotropy artifacts. No manual alignment is required when the detector and/or optical filters are exchanged.
    Lock-in detection by DSP
    Phase-sensitive lock-in detection by DSP (Digital Signal Processing) with a sophisticated algorithm optimized for VCD offers drastic improvement of the S/N ratio.
    Purge capability
    The optics, sample chamber and detector housing are all purgeable to obtain high-precision data free of environmental interference.

  • Measurement wavenumber range

    Standard: 3200 ~ 850 cm-1
    Option: 4000 ~ 750 cm-1

    Resolution

    16 ~ 0.5 cm-1

    Noise level
    (measurement conditions)

    less than 8 x 10-6ΔAbs
    (4 cm-1, 20 min accumulation)

    Light source

    High intensity ceramic source, insulated mount

    Interferometer

    28° Michelson interferometer

    Optical filter

    Standard:
    3200 ~ 2000 cm-1
    2000 ~ 850 cm-1
    (6-position automatic switching)
    Option:
    4000 ~ 2700 cm-1,
    1000 ~ 750 cm-1,
    1850 ~ 1550 cm-1

    Polarizer

    KRS-5

    Detector

    Standard:
    MCT-V (3200 ~ 850 cm-1)
    Option:
    MCT-C (1000 ~ 750 cm-1)
    InSb (4000 ~ 2000 cm-1)

 
Scroll