technology

right Chemistry See all product

TORNADO LITE Nitrogen Gas Generator

☆☆☆☆☆ ( 0 rates ) 453
Price : Call

Code: #19148

Supplier: F-DGSi

The nitrogen generators serie Tornado Lite offer to you a unique, innovative solution to nitrogen gas supply.

A reliable, secure source of nitrogen can be produced from your existing compressed air supply, eliminating the need for liquid nitrogen or high pressure gas cylinders.

Conceived for a continuous operation, the Tornado Lite nitrogen generator can produce flow rates from a few liters per minutes to over NL/min at purities in oxygen content residual from 10 ppm to 3%.

The generator is controlled using the latest in HMI touch screen technology to display the process, pressures, inlet air dewpoint and oxygen levels with continuous monitoring complete with alarms.

rightMORE INFORMATION

    • Fully regenerative PSA technology : reduced risk of gas contamination and phthalate free
    • Varying flow rates and purities
    • HMI touch screen technology to display the process in real time, including process variables
    • Oxygen sensor display with alarm
    • Air inlet dewpoint display with alarm
    • Audible alarm display and Visual maintenance indication with history log
    • Analogue connections
    • IP address for remote access via internet connection
    • Quick and easy maintenance : access from front, no rear access required
    • Automatic economy mode : enable to go in standby mode when no N2 is required

  • FACTOR OF CORRECTION
    Pressure (bar) 7.5 8 8.5 9 9.5
    Pressure (psi) 109 116 123 130 138
    Factor of correction1.141.211.291.36
    MODELS10 ppm100 ppm0.10%0.5%1.0%2.0%3.0%4.0%5.0%Dimensions (W x H x D)Weight (kg/lbs)
    N2 FLOW RAT NL3/min VIA O2 PURITY
    TORNADO-102L 10 20 30 45 50 70 85 40 x 115 x 58 cm (16″ x 69″ x 23″) 150 / 330
    TORNADO-104L 20 40 60 90 100 140 170 180 / 396
    TORNADO-106L 30 60 90 135 150 210 255 40 x 115 x 76 cm (16″ x 69″ x 30″) 230 / 5077
    Air/N2 ratio 10.8 5.9 3.6 3.4 2.8 2.6 2.4 2.2 2.1
    TECHNICAL DATA
    Temperature range 5 – 45°C (41 – 113°F)
    Air Inlet Pressure 6 – 16 bar (87 – 232 psi)
    Nitrogen Outlet Pressure 5 – 14 bar (72 – 203 psi)
    Air Inlet quality requirement Dew Point : -40°C (-40°F)
    Particulate : < 0.1 micron
    Oil : < 0.01 mg/m³
    Electrical Supply 90 – 260 V ac / 1 ph / 50 – 60 Hz
    Power 0.2KW
    Signal / monitoring no volt alarm & RS232
    Inlet/Outlet connections G 1⁄2 (BSP) F

  • ECONOMY SAVING

    – Quick return on investment < 1 year

    – After installation, the generator require minimal attention and Maintenance.

     

    RELIABILITY AND SAFETY OF USE

    – Nitrogen produced at low pressure and ambient temperature removes the hazards associated with high pressure cylinders and liquid Dewar’s

    – Nitrogen available on request 24H per day ensuring the walk of the process in a regular and uninterrupted way

     

    COMPACT DESIGN AND FLEXIBLE MODULAR OPTION

    – The system demands less floor space
    – The modular concept means the generators can be multi banked if required (Master/Slave configuration) Evolutionary System adapting as your business grows and gas requirements change

 