technology

right Materials and Metallurgy See all product

L76 Platinum Series Dilatometer

☆☆☆☆☆ ( 0 rates ) 913
Price : Call

Code: #15752

Supplier: T&N Trading And Investment Company Limited (T&N TRAVES CO., LTD)

 

  • The main application field for the LINSEIS L76 Dilatometer series is the CTE measurement of ceramics, brick, tile, porcelain and building materials. Furthermore it is widely used for quality control purposes in ceramics and in metal industries.
  • Thanks to the fact we started to develop and build Dilatometers in the year 1955, this instrument is very reliable and covers a wide temperature range from RT up to 1000°C, 1400°C and 1600°C with user exchangeable furnaces. It consists of measurement systems made out of quartz glass (up to 1100°C) and Al2O3 (up to 1600°C).
  • The sensor is a highest precision LVDT (linear variable differential transformer), which has an indefinite resolution. Together with the 32 Bit software package LINSEIS WIN-TA / WIN-DIL, the Dilatometer provides an excellent solution for standard quality control type CTE measurements.
  • The following physical properties can be measured:
  • CTE, Linear Thermal Expansion, Alpha Physical, Sintering Temperature, Phase Transformations, Softening Points, Decomposition Temperatures, Glass Transition Temperatures.

 

rightMORE INFORMATION

  •  

    • Glass transition and softening point evaluation
    • Softening point detection with automatic software controlled system shut down
    • Display of relative/absolute shrinkage or expansion curves
    • Presentation and calculation of technical / physical expansion coefficient
    • Rate Controlled Sintering (RCS) Software
    • Sinter process evaluation
    • Semiautomatic evaluation functions
    • Several system correction features
    • Automatic zero point adjustment
    • Automatic software controlled sample pressure adjustment

     

  • Temperature range:

    RT … 1600°C

    LVDT:

     

    Delta L resolution:

    0,05 nm

    Measuring range:

    +/- 2500 µm

    Contact force:

    50 mN up to 1 N

    Optical Encoder:

     

    Delta L resolution:

    1 nm

    Measuring range:

    +/- 25000 µm

    Automatic sample length detection:

    yes

    Force modulation:

    no

    Contact force:

    50 mN up to 3N

    Multiple furnace configuration:

    optional

    Motorized furnace operation:

    optional

    Gas dosing:

    manual gas dosing or mass flow controller 1/3 or more gases

     

    Contact force adjustment:

    Single/double dilatometer:

    Softening point detection:

    included

    Density determination:

    optional

    L-DTA:

    optional

    Rate Controlled Sintering (RCS):

    optional

    Thermal library:

    optional

    Electric thermostatization of measuring head:

    included

    Low temperature options:

    LN2

    Vacuum tight design:

    Automatic evacuation system:

    OGS Oxygen Getter System:

 
Scroll