technology

right Chemistry See all product

Geno™ Type 2 Water | Deionised Water Purification System

☆☆☆☆☆ ( 0 rates ) 556
Price : Call

Code: #20497

Supplier: Avidity Science Ltd.

Geno™ Deionised (DI) water purification systems for laboratories and hospitals. Produces Type 2 General Laboratory Grade Water

rightMORE INFORMATION

  • Geno™ - Delivering Type 2 Deionised Water At The Rate You Need

    The Geno™ water purification system takes RO water to the next level of purity, providing DI laboratory grade water in three convenient production rates of 10, 20 or 50 litres per hour. The Geno™ combines all the latest technologies to produce Type 2 DI water. The Endure DI packs are simple to change and long lasting.


     

    Type 2 Water Applications

    The Geno™ is suitable for DI water usage of 10-400 litres per day. Type 2 DI water is suitable for:

    • Buffer and Media Production
    • Sample Dilution and Reagent Preparation
    • Spectrophotometry
    • Protein Electrophoresis
    • Cytology & Histology
    • Glassware Washing & Rinsing

  • Type 2 water using reverse osmosis and deionisation technology 

    • 1-15 MΩ-cm
    • Type 2 Water Quality general laboratory grade water
    • >50% recovery of RO water
    • Novel recirculation process extends life of RO membrane and DI cartridges
    • TOC <50ppb
    • Operates at 0.1-6 bar feed water pressure
    • Up to 98% rejection of inorganics
    • Compact design
    • Wall mounting brackets included
    • Bench, reservoir-top or wall mounting
    • Excellent monitoring of conductivity
    • SD Card interface
    • Choice of 30/60/100 litre capacity reservoir               


    PRODUCT WATER QUALITY

    MODEL

    DI MAKE UP RATE (@15°C)

    INORGANICS REJECTION RATE**

    DI QUALITY (@25°C)

    DISPENSE RATE (@15°C FROM TANK)*

    TYPICAL TOC REDUCTION***

    GENO10 10L/hr 98% 1 - 15MΩ-cm 3 - 7L/min 96%
    GENO20 20L/hr 98% 1 - 15MΩ-cm 4 - 7L/min 96%
    GENO50 50L/hr 98% 1 - 15MΩ-cm 5 - 7L/min 96%

    * Depending on tank and pump setup

    ** Depending on feedwater impurities

    *** Using tank UV option


    SYSTEM REQUIREMENTS

    FEED WATER



    Pressure Bar 0.1 - 6
    Conductivity μS/cm <1400
    Temperature °C 4 - 30
    Hardness as CaCO3 ppm <400
    Free Chlorine ppm <2
    Colloid Index SDI <3
    pH Value
    4 - 10
    Iron (Total Fe) ppm <0.1


    UNIT SPECIFICATIONS

    ALL MODELS


    Dimensions (HxWxD) 500 x 490 x 290mm
    Installed Weight 23kg
    Power Supply 100 - 240V ~; 50/60Hz; 3.0A (max)
    Power Supply Output 24VDC, 5.OA, 120W (max)
    Operating Temperature 4°C - 35°C (max)
    Storage Temperature 4°C - 35°C (max)


    UTILITIES & SERVICES

    REQUIREMENTS


    Water Supply Isolated cold-water feed
    Drain Type Sink/Tundish/Standard up-stand with suitable trap
    Drain Flow >3L/min


    CONSUMABLES & ACCESSORIES

    PART NUMBER

    DESCRIPTION

    TYPICAL ANNUAL REQUIREMENT

    TC001 Pre-treatment Module 2
    TC002 Endure™ Purification Pack 1 2
    TC005 Tank Vent Filter 1
    TANK30 30 Litre Tank -
    TANK60 60 Litre Tank -
    TANK100 100 Litre Tank -
    TANK100P-1 100 Litre Tank with Pump - 230V -
    TANK100P-2 100 Litre Tank with Pump - 110V -
    AV004 Valve Kit for Washing Machine Feed (Single POU) -
    AV006 Wall Mounting Kit -
    AV007 External Pre-filter Housing Kit (Excludes Filter) -
    AV016 Valve Kit for Washing Machine Feed (Double POU) -


    TYPE 2 WATER

    APPLICATIONS

    Buffer & Media Preparations
    Sample Dilution & Reagent Preparation
    Spectrophotometry
    Protein Electrophoresis
    Cytology & Histology
    Glassware Washing & Rinsing


     

    RESERVOIRS

     

    WIDTH

    HEIGHT

    DEPTH

    TANK30

    410mm

    500mm

    240mm

    TANK60

    485mm

    500mm

    330mm

    TANK100

    485mm

    800mm

    340mm

    TANK100PUMP*

    485mm

    800mm

    340mm

    *100 litre tank with built-in pump to provide the correct pressure for feeding washing machines, glasswashers and remote points of use.  

    • Including dispense tap on front of the reservoir in the middle or at the bottom
    • 3/4” BSP glass-washer outlet
    • Pressure sensor level control, with a 0-100% contents display
    • 0.2μm microbiological air vent filter or an optional CO2 filter
    • 30 and 60 litre reservoirs are wall mountable 


    SERVICES REQUIRED

    3/4” BSP isolated cold water feed (washing machine tap/valve)

    240 Volt, 13 Amp sockets

    Drain/up-stand with trap or sink/tundish


    OPTIONAL LEAK DETECTION

    If your water system is in a location where a leak could cause damage or health and safety issues, we recommend that you protect against this possibility by means of a leak detector, or for larger systems a containment bund. Containment bunds, price available on application. The following are available from Avidity Science: 

    PART NO.

    DESCRIPTION

    2084

    Water Guard for small laboratory equipment up to 100L/hr

    00029

    Water Guard for larger equipment with a feed connection up to ¾”

    • Low running costs
    • Easy to change consumables with realistic costs
    • Bench, wall or reservoir top mounting
    • Choice of storage reservoir, 30, 60 or 100 litres
    • Choice of production rates depending on how much water you need during the day
    • Integral boost pump

    The integral boost pump avoids unexpected costs by providing an uninterrupted feed water supply. The Geno™ is fed directly from your mains water supply.

 
Scroll