PetroAlert 9200 GC & Total Gas

☆☆☆☆☆ ( 0 rates ) 396
Price : Call

Code: #19472

Supplier: Ametek GmbH Mocon

Surface Logging GC/THA with dual FIDs

  • Surface Logging Applications
  • Accurate, interference free, detection
  • Dual GC analysis capable, or GC with total gas
  • Custom analyses available

rightMORE INFORMATION

  • The PetroAlert® 9200 gas analyzer combines the selective detection of a gas chromatograph (GC) with the continuous monitoring abilities of a total hydrocarbon analyzer (THA) in a single, compact, sensitive and stable instrument.

     

    The PetroAlert 9200 is specifically engineered to meet the requirements of the oil and gas industry’s exploratory surface logging process. Its speed and accuracy allow well loggers monitoring a drill site to analyze the hydrocarbons within a well, both quantitatively and qualitatively, while drilling. That ability makes for a more efficient drilling process and more timely evaluation of a well’s potential. Each PetroAlert is factory-configured to meet specific customer monitoring requirements.

     

    The analyzer incorporates dual-flame ionization detectors (FIDs): one dedicated to the GC and the other dedicated to total hydrocarbon measurement. The GC performs fast C1 to C5 analysis (< 30 seconds, preserving the C1-C2 separation at 200:1 concentration ratios) with a detection limit of < 10 ppm as methane (CH4), while the total hydrocarbon detector continuously monitors total hydrocarbons down to 0.003% and up to 100% as CH4. The analyzer's automatic calibration feature is ideal for unattended operation. Custom GC applications are available upon request.

     

    Our PetroAlert analyzers are industry proven and adopted worldwide by major oil and petrochemical companies as the finest FID-based hydrocarbon field analyzers available while providing automated lab quality data.

  • PetroAlert® 9200 GC & Total Gas

    Units

    Detector

    Dual Flame Ionization Detectors (FID)

    Sampling

    Single point
    Internal pump optional

    Columns

    Packed, micro-packed, or capillary specific to application

    Connections

    1/4”or 1/8” OD tube compression fitting or 1/8” legris

    Alarms

    Multilevel concentration and fault alarms, audible and visual

    Calibration

    Automatic or manual using a dedicated standard

    Calibration Methods

    Gas cylinder or response factors

    Display

    7” color LCD touchscreen

    Outputs/Inputs, Standard

    RS-232
    LAN/Ethernet
    2 USB ports for mouse, keyboard or external storage

    Outputs/Inputs, Optional

    I/O Board: 6 digital inputs, 5 relays as contact closures, 1 analog
    Analog Board: 4 or 8 configurable as 4-20mA or 0-20mA
    Relay Board: 8 or 16 programmable contact closures

    Operating Temperature

    32 to 104°F (0 to 40°C)

    Operating Humidity

    0 to 95% (non-condensing)

    Configuration

    Benchtop or 19” (48.3cm) rack-mount, 3U

     

    Other Specifications (all models):

    Physical Specifications

    • 5.12” H x 19” W x 22.4” D (13 cm x 48.26 cm x 56.9 cm)
    • <30 Lbs. (13.64 kg)

    Electrical Requirements

    • Voltage: 100 - 230 VAC 50/60 Hz, 2 A
     

  • Automated Control Features
    • FlowGuard control of fuel, air, and sample with automatic shut-off
    • Automatic FID ignition
    • Electronic back-pressure regulator with sample bypass system
    • Automatic calibration at user-defined intervals
    • Continuous unattended operation
    Versatile Platform
    • Graphic LCD display with easy to use menu
    • Benchtop or rack-mountable
    • WITS output
    • Customizable ethernet and serial output
    • Programmable analog output ranges
    • Programmable relays for diagnostics, concentration, alarms, and events

 