technology

right Chemistry See all product

Density / Specific Gravity Meter DA-650/645/640

☆☆☆☆☆ ( 0 rates ) 87
Price : Call

Code: #29710

Supplier: Kyoto Electronics Manufacturing Co., Ltd.

- Equipped with sampling and dry pump
- Measuring Range:±0 – 3 g/cm3
- Temp Range:±0 – 96℃ (32 – 204.8°F)

rightMORE INFORMATION

  • Type

    Density / Specific Gravity Meter

    Model

    DA-650/645/640

    Measurement Method

    Resonant frequency oscillation

    Measurement Range

    03 g/cm3

    Measurement Temp Range

    0 - 96 (32 - 204.8°F)

    Accuracy*1

    Density :
    DA-650 : ±2 x 10-5/gcm3(±0.00002 g/cm3)
    DA-645 : ±5 x 10-5g/cm3(±0.00005 g/cm3)
    DA-640 : ±1 x 10-4g/cm3(±0.0001 g/cm3)
    (Calibration with air and water required.)

    Temp :
    DA-650 : ±0.02°C(±0.04° F)
    DA-645 : ±0.03°C(±0.05° F)
    DA-640 : ±0.05°C(±0.09° F)

    Repeatability*2

    Density :
    DA-650 : SD 5 x 10-6g/cm3
    DA-645 : SD1 x 10-5g/cm3
    DA-640 : SD 5 x 10-5g/cm3

    Minimum Sample Required

    1) Approx. 1mL (Syringe) 2) Approx. 2mL (Pump)

    Measurement Time

    1) 1 to 4 mins (Manual) 2) 2 to 10 mins (Auto)

    Display

    1) 5.7-inch colour TFT LCD; 640 x 480
    2) Shows density, specific gravity, oscillation frequency, temperature, concentration and other messages.

    Viscosity Correction

    Yes

    Sampling

    1) Manual by syringe
    2) Auto by peristaltic pump

    Method

    Saves up to 100 different methods in built-in memory

    Stability

    Four modes of stability according to measurement accuracy and time

    Density Auto Correction

    1) Saves conversion table or formula at your desired temperatures according to your samples.
    2) Temperature conversion table programmed according to ASTM standard for petroleum, petroleum products and lubricating oils.

    Auto Conversion

    1) Between concentration and density
    2) Between temperature and density

    Statistics

    1) Auto or manual calculation of mean value, SD and coefficient
    2) Recalculation, data deletion

    Interfaces

    1) LAN:
    x 1; Personal computer (PC)
    2) USB 1.1:
    x 2; USB flash drive, keyboard,
    barcode reader, Epson inkjet printer *3
    3) RS232C:
    x 2; Dot Matrix Printer,
    Auto Clean and Sampling Unit,
    Multiple Sample Changer

    Options

    1) Printer : DP-600, IDP-100
    2) Sampling unit, Changer : DCU-551N/H, CHD-502N/H/C
    3) Software : SOFT-CAP (Data Acquisition Software)

    Data I/O

    1) USB flash drive as data storage medium
    2) Application Notes provided in USB flash drive

    Wetted Materials

    PTFE, borosilicate glass, SUS304

    Ambient Conditions

    1) Temperature : 5 – 35 (41 - 95°F)
    2) Humudity : 85%RH or below (No condensation allowed)

    Power Supply

    AC100 – 240V; 50/ 60Hz (Comes with AC adapter)

    Power Consumption

    40W (max. 120W, min.20W)

    Dimensions

    320 (W) x 365 (D) x 250 (H) mm
    (12.6 (W) x 14.4 (D) x 9.8 (H) inches)

    Weight

    18kg (39.7Ibs)

    Export Packing in Double Carton Box

    G/W 21kg; 540 (W) x 480 (D) x 460 (H) mm
    (G/W 46.3Ibs; 21.3 (W) x 18.9 (D) x 18.1 (H) inches)
    (May vary in some cases)

  • - Hassle-free and safe measurement
    - Easy check of measurement cell
    - No air bubbles, no contamination
    - Calibration at one temperature
    - Easy data transfer
    - Connection to barometer (Option / NON-CE)

 
Scroll