technology

right Agriculture See all product

S40 Bluetooth Water Hardness Meter

☆☆☆☆☆ ( 0 rates ) 325
Price : Call

Code: #20644

Supplier: Bante Instruments

High-performance wireless bluetooth water hardness meter, suitable for Android smartphone or tablet, 2 to 5 points calibration, setup menu contains 12 options, accuracy: 1% F.S.

rightMORE INFORMATION

  •    Model


    S40

       Water Hardness



       Range (Concentration)


    0.05 to 200mmol/L

       Range (German Degree)


    0 to 1122°dH

       Range (English Degree)


    0 to 1404°e

       Range (French Degree)


    0 to 2000°fH

       Range (Grains per gallon)


    0 to 1170gpg

       Range (CaCO3)


    0 to 20000mg/L

       Range (CaO)


    0 to 11220mg/L

       Range (Ca2+)


    0 to 8020mg/L

       Resolution


    0.001, 0.01, 0.1, 1

       Accuracy


    ±1% F.S.

       Calibration Points


    2 to 5 points

       Calibration Solutions


    0.01, 0.1, 1, 10, 100mmol/L

       mV



       Range


    ±2000.0mV

       Resolution


    0.1, 1mV, selectable

       Accuracy


    ±0.2mV

       General Specifications



       Temperature Compensation


    0 to 50°C/32 to 122°F, manual

       Stability Criteria


    Fast, standard, slow

       Measurement Modes


    Continuous or auto-read

       Timed Interval Readings


    10, 30, 60, 300 seconds or off

       Calibration Due Alarm


    1 to 99 days or off

       Data Transfer


    Send to memory or printer

       Password Protection


    6 digits

       Connectivity


    Bluetooth 4.0 or later

       Max Wireless Range


    10m/32.8ft

       Power


    2×1.2V lithium batteries or AAA batteries

       Dimensions


    175(L)×40(Dia.)mm

       Weight


    100g

  • • High-performance bluetooth water hardness meter is supplied with a solid state sensor.
    • 2 to 5 points calibration, providing the 5 concentration points can be selected.
    • Selectable water hardness units - german degree (°dH), english degree (°e), french degree
      (°fH), gpg, mg/L and mmol/L.
    • Manual temperature compensation eliminates the error caused by temperature deviation.
    • Auto-Read function senses and locks the measurement endpoint.
    • Timed Interval Readings sends the measurement data to memory or printer.
    • Limit Alarm automatically alerts when reading exceeds the specified range.
    • Calibration due alarm prompts user to calibrate the tester regularly.
    • Calibration report shows the date, time, calibration points and slopes.
    • Password protection prevents the unauthorized calibration and settings.
    • Multiparameter measurement allows the bluetooth conductivity and dissolved oxygen testers
      connect to device simultaneously.
    • Reset function automatically resumes all settings back to the factory defaults.

 
Scroll