Horiba EMIA-V2 series Carbon/Sulfur Combustion Analyzer

☆☆☆☆☆ ( 0 rates ) 719
Price : Call

Code: #14421

Supplier: HORIBA, Ltd.

The EMIA-V2 series measures carbon and sulfur extracted during combustion in a programmable High Frequency furnace without conversion. Combustion control is achieved through the use of the high-frequency induction furnace method. Appropriate heat-control in accordance with the analysis objective enables high-precision analysis for all types of samples.

rightMORE INFORMATION

  • The EMIA-V2 series measures carbon and sulfur extracted during combustion in a programmable High Frequency furnace without conversion. Combustion control is achieved through the use of the high-frequency induction furnace method. Appropriate heat-control in accordance with the analysis objective enables high-precision analysis for all types of samples. A variety of models allow you to select the furnace system that is best suited to your target samples and application
    - EMIA-920V2 C/S analyzer: High performance analyzers with outstanding accuracy of less than 0.3ppm
    - EMIA-320V C/S analyzer: Standard performance analyzers for wide range of applications.
     
    Features:
    - "Auto cleaner" mechanism reduced maintenance works (Standard for 920V, Option for 320V2)
    - The Dust filter heating mechanism provides stable analysis with extremely low gas absorption (920V2 only)
    - Real-time simultaneous detection of CO/CO2/SO2 without an oxidizing (CO→CO2) or SO3 trapping reagents.
    - Wide variety of self diagnostics
    - Programmed temperature curve for optimizing combustion.
    - Choose from standard or wide range models to suit your application requirements.

  • EMIA-920V2 series:

    EMIA-920V2

    Simultaneous carbon/sulfur analysis

    EMIA-921V2

    Carbon analysis

    EMIA-922V2

    Sulfur analysis

    Principle

    NDIR/ Non Dispersive Infrared Gas Anaryzer
    High-frequency furnace method in oxygen flow

    Range

    arbon: 0-6,0%, Sulfur: 0-1,0%
    Up to 100% wt is possible by decreasing the sample weight.

    Accuracy

    Carbon:
    Concentration less than 20 ppm >>> σn-1
    0.3 ppm
    Concentration higher than 20 ppm >>> σn-1
    1 ppm or RSD 0.5%

    Sulfur:
    Concentration less than 20 ppm >>> σn-1
    0.3 ppm
    Concentration higher than 20 ppm >>> σn-1
    1 ppm or RSD 0.75%

    Sample weight

    1,0g standard

    Sensitivit

    0,01ppm

    Analysis time

    Normally 30 to 60 seconds(after combustion),varies according to the characteristics of the samples

    Calibration

    One-point or multi-point calibration using standard sample

    Combustion furnace method/furnace structure

    High-frequency induction furnace method with combustion control function (patent pending)
    Anode output: 2300W
    Frequency: 20MHz
    Plate current: Settable up to 500mA
    Automatic control possible (10 slopes maximum)
    Constant dust filter heating function

    Operation gas

    Oxygen purity: More than 99.5%
    Dry air or nitrogen: Supply pressure 0.35MPa

    Functions

    Interrupt analysis
    Self diagnosis
    Data storage(Measurement results)
    Traceability of calibration curve and measurement conditions
    Statistic calculation
    Maintenance navigator

    Automatic cleaning mechanism

    Built-in as standard

    Oxygen gas purifying unit

    Built-in as standard

    Power

    Main unit: AC200/220/240V 5kVA 50/60Hz
    PC: AC100V, 120/200/220/240V 0.5kVA 50/60Hz

    Dimensions

    560(W)×927(D)×950(H)mm Approx.170 kg

    EMIA-320V2 series:

    EMIA-320V2

    Simultaneous carbon/sulfur analysis

    EMIA-321V2

    Carbon analysis

    EMIA-322V2

    Sulfur analysis

    Principle

    NDIR/ Non Dispersive Infrared Gas Anaryzer
    High-frequency furnace method in oxygen flow

    Range

    Carbon: 0-6.0%, Sulfur: 0-1.0%
    Up to 100% wt is possible by decreasing the sample weight.

    Accuracy

    Carbon: σn-12 ppm or RSD1.0%
    Sulfur: σn-1
    2 ppm or RSD1.5%

    Sample weight

    1,0g standard

    Sensitivity

    0,1ppm

    Analysis time

    Normally 30 to 60 seconds(after combustion),varies according to the characteristics of the samples

    Calibration

    One-point or multi-point calibration using standard sample

    Combustion furnace method/furnace structure

    High-frequency induction furnace method with combustion control function (patent pending)
    Anode output: 2300W
    Frequency: 20MHz
    Plate current: Settable up to 500mA
    Automatic control possible (10 steps maximum)

    Operation gas

    Oxygen purity: More than 99.5%
    Dry air or nitrogen: Supply pressure 0.35MPa

    Functions

    Interrupt analysis
    Self diagnosis
    Data storage(Measurement results)
    Memory of calibration curve and measurement conditions
    Statistic calculation

    Automatic cleaning mechanism

    Option

    Oxygen gas purifying unit

    Option

    Power

    Main unit: AC200/220/240V 5kVA 50/60Hz
    PC: AC100V, 120/200/220/240V 0,5kVA 50/60Hz

    Dimensions

    560(W)×885(D)×820(H)mm Approx.170 kg

 