Model |
| Bante900 |
pH |
|
|
Range |
| -2.000 to 20.000pH |
Resolution |
| 0.001, 0.01, 0.1pH, selectable |
Accuracy |
| ±0.002pH |
Calibration Points |
| 1 to 5 points |
pH Buffer Options |
| USA, NIST, DIN, 2 custom buffers |
ORP |
|
|
Range |
| ±1999.9mV |
Resolution |
| 0.1, 1mV, selectable |
Accuracy |
| ±0.2mV |
Calibration Points |
| 1 point |
Measurement Modes |
| Relative or absolute mV |
Ion Concentration |
|
|
Range |
| 0.001 to 19999 (deponding on the range of ISE) |
Resolution |
| 0.001, 0.01, 0.1, 1 |
Accuracy |
| ±0.5% F.S. (monovalent), ±1% F.S. (divalent) |
Calibration Points |
| 2 to 5 points |
Calibration Solutions |
| 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 |
Measurement Units |
| ppm, mg/L, mol/L, mmol/L |
Conductivity |
|
|
Range |
| 0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Resolution |
| 0.001, 0.01, 0.1, 1 |
Accuracy |
| ±0.5% F.S. |
Calibration Points |
| 1 to 5 points |
Calibration Solutions |
| 10µS, 84µS, 1413µS, 12.88mS, 111.8mS |
Temperature Coefficient |
| Linear (0.0 to 10.0%/°C), pure water |
Reference Temperature |
| 20/25°C |
Cell Constant |
| K=0.1, 1, 10 or custom |
TDS |
|
|
Range |
| 0.00 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
Resolution |
| 0.01, 0.1, 1 |
Accuracy |
| ±1% F.S. |
TDS Factor |
| 0.1 to 1.0 (default 0.5) |
Salinity |
|
|
Range |
| 0.00 to 80.00ppt, 0.00 to 42.00psu |
Resolution |
| 0.01 |
Accuracy |
| ±1% F.S. |
Resistivity |
|
|
Range |
| 0.00 to 20.00MΩ |
Resolution |
| 0.01 |
Accuracy |
| ±1% F.S. |
Dissolved Oxygen |
|
|
DO Range |
| 0.00 to 20.00mg/L |
Resolution |
| 0.01, 0.1mg/L, selectable |
Accuracy |
| ±0.2mg/L |
% Saturation of Oxygen |
| 0.0 to 200.0% |
Resolution |
| 0.1, 1%, selectable |
Accuracy |
| ±2.0% |
Calibration Points |
| 1 or 2 points |
Pressure Correction |
| 60.0 to 112.5kPa/450 to 850mmHg, manual |
Salinity Correction |
| 0.0 to 50.0g/L, manual |
Temperature |
|
|
Range |
| 0 to 105°C/32 to 221°F |
Resolution |
| 0.1°C/0.1°F |
Accuracy |
| ±0.5°C/±0.9°F |
Offset Calibration |
| 1 point |
Calibration Range |
| Reading ±10°C |
General Specifications |
|
|
Temperature Compensation |
| 0 to 100°C/32 to 212°F, manual or automatic |
Stability Criteria |
| Low or high |
Calibration Due Alarm |
| 1 to 31 days or off |
Memory |
| Stores up to 500 data sets |
Output |
| USB communication interface |
Connector |
| BNC, 6-pin nimi-DIN, 3.5mm jack socket |
Display |
| Custom LCD (125×100mm) |
Power |
| DC5V, using AC adapter, 220V/50Hz |
Dimensions |
| 210(L)×188(W)×60(H)mm |
Weight |
| 1.5kg |